MR/MRD SERIES UPS SYSTEMS : True Online Double Conversion Intelligent Sinewave Suitable for industrial applications & extreme conditions 700VA - 2000VA Click on the pictures below to view full specifications on the UPS system |
![]() |
|||||
|
The exceptional MR / MRD Series delivers the most comprehensive uninterruptible power protection on the marketplace.
These models are recognised worldwide by users for their true on-line double conversion topology, highly efficient operation, true isolation, near unity input power factor and superior output voltage regulation.
The MR / MRD Series features a wide input mains voltage range virtually eliminating unnecessary battery discharges ensuring that the batteries are reserved for true emergency conditions. The input mains voltage range for the MR / MRD Series is between 90-130VAC for 120VAC models and 160-270VAC for 230VAC models.
|
![]() ![]()
|
||||||
| TECHNICAL SPECIFICATIONS | |||||||
| MODEL | LED DISPLAY |
MR600 |
MR1000 |
MR1500 |
MR2000 |
MR611 |
MR1011 |
| LCD DISPLAY |
MRD600 |
MRD1000 |
MRD1500 |
MRD2000 |
MRD611 |
MRD1011 |
|
|
Output |
VA Rating |
600 VA |
1000 VA |
1500 VA |
2000 VA |
600 VA |
1000 VA |
|
Wattage |
420 W |
800 W |
1050 W |
1400 W |
420 W |
700 W |
|
|
Current (Max) |
2.7 A |
4.3 A |
6.5 A |
8.7 A |
5.2 A |
8.7 A |
|
|
Voltage |
220 V, 230 V, 240 V ± 2% |
100 V, 110 V, 120 V ± 2% |
|||||
|
Frequency |
50 / 60 Hz |
60 Hz |
|||||
|
Waveform |
Pure Sinewave |
||||||
|
Harmonic Distortion |
Less than 3% at full linear load |
||||||
|
Input |
Voltage |
160 V - 270 V |
90 V - 130 V |
||||
|
Frequency |
50 / 60 Hz ± 5% |
60 Hz ± 5% |
|||||
|
Runtime |
Full Load |
8 min. |
10 min. |
10 min. |
10 min. |
8 min. |
10 min. |
|
Half Load |
25 min. |
||||||
|
Transfer Time |
UPS to Bypass |
Less than 4 msec. |
|||||
|
Zero-Cross Trans. |
0 msec. to or from battery |
||||||
|
Battery |
Type |
12V / 7AH Lead acid maintenance free |
|||||
|
DC Voltage |
24 VDC |
48 VDC |
72 VDC |
96 VDC |
24 VDC |
48 VDC |
|
|
Recharge Time |
5 - 8 hours |
||||||
|
Recharge Current |
1.5 A |
||||||
|
Efficiency |
AC to AC |
80% min. |
|||||
|
Audible Noise |
< 45 dBA at one metre |
||||||
|
Indicators |
LED Display |
LINE, INV., BYPASS, FAULT, LOAD LEVEL and BAT. LEVEL |
|||||
|
Audible Alarm |
Battery Discharge |
Sounding every 6 seconds after mains fail and every second when approaching final discharge |
|||||
|
Alarm Reset |
Press once to stop alarm at back-up mode |
||||||
|
Fault |
Continuous beeping sound |
||||||
|
Auto Restart |
When AC line recovers after shutdown by remote LAN signal or end of battery discharge |
||||||
|
DC Start-up |
Yes |
||||||
|
Protection |
Overload |
> 110% of full load with 20 sec. delay |
|||||
|
Over/Under Volt. at INV.O/P |
Inverter shutdown protection |
||||||
|
Short Circuit |
The UPS shuts down and will not transfer to the bypass mode when a short circuit occurs on the output of the unit. After the short circuit is removed, the UPS will operate normally again. At short condition, the FAULT LED lights as a warning to end-users (600VA excluded). |
||||||
|
Lightning & Surge |
Passes ANSI/IEEE587 Cat.A |
||||||
|
EMC/LVD1230V 50Hz |
EN50091-2/EN50081-1 |
||||||
|
Safety |
TUV GS Mark EN50082-1 |
||||||
|
LAN Interface |
DB9/RS232 Interface |
Mains fail, battery low and remote shutdown UPS |
|||||
|
Mechanical |
Dimensions (W x H x D) (cm) |
14 x 19 x 44 |
18 x 30 x 40 |
18 x 30 x 47 |
18 x 32 x 49 |
14 x 19 x 44 |
18 x 30 x 40 |
|
Weight (kg) |
12 |
22 |
30 |
38 |
12 |
22 |
|
|
Environment |
Temperature |
0 deg - 40 deg C |
|||||
|
Humidity |
0 - 95% Non-Condensing |
||||||